PowerWAVE 3000/TP

One of the most compact single phase UPS systems delivering critical power protection of up to 80 kVA. Designed for mid-size server rooms, the PowerWAVE 3000/TP offers unrivalled efficiency, reliability and scalability for industrial processes, networks and telecommunications systems. A best-in-class UPS system which is simple to install, run and maintain.

Description

Available in both 10 and 20 kVA solutions, this is one of the most stable uninterruptible power supplies, offering regulated and transient-free power with a small footprint and high energy efficiency.

Highly reliable

Built with online double conversion topology, the PowerWAVE 3000/TP delivers a constant and stable power supply system.

Flexible and scalable

Single or three-phase input provides flexibility for different installation requirements. Pay-as-you-grow scalability offers increased power supply across up to four units.

Innovative monitoring devices

Dry-contact cards, network interface cards and responsive sensors allow the single phase UPS system to be closely monitored for faults.

Highly efficient to reduce running costs

Reduced heat loss keeps the UPS system at an optimum temperature without wasting energy. Helps to maintain backup UPS battery life and reduce running costs.

LCD display

Bright LCD display provides quick access to vital information about system performance for instant monitoring. LEDs provide immediate information about system status.

Kohler Uninterruptible Power is one of the leading single phase UPS suppliers in the UK. To request more details about the PowerWAVE 3000/TP make an enquiry using the form below or call us on 0800 731 3269.

Additional information

Actual kVA

10kVA & 20kVA

Type

Single phase, Three phase

Power range per module

10kVA or 20kVA

Parallelable up to

4 x UPS units

Rated output voltage range

220/230/240V single phase

Working mode

Online double conversion

Efficiency

Up to 93%

Power density per m2

Up to 45kW/m2 / 65kVA/m2

Battery compartment

Included in UPS cabinet

Maintenance bypass

Standard

Network/web interface

Option

Volt free contacts

Standard

Input current distortion THDi @100% load

<5% linear load, <7% non-linear

Input power factor @100% load

0.99

Scalable (N+1)

Yes (vertical)

Hot-swappable modules

No

ECA scheme approved

No

Transformerless

Yes

Application

Small Business

Standalone / Modular

Standalone

Documentation

GET A QUOTE

Are you interested? Call us on 01256 386700 or complete the form below, and let us supply you with a quote. Required Info*








We would like to keep in touch with you from time to time! If you would like to hear from us, please let us know what you are interested in:

To learn more about these options and what they mean, please view our Marketing Communications page.

Related products

  • PowerWAVE-1000-3kVA

    PowerWAVE 1000 3kVA

    £848.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    3 kVA
    3 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
  • PowerWAVE-1000-6kVA

    PowerWAVE 1000 6kVA

    £1,715.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    6 kVA
    6 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
  • PowerWAVE-1000-10kVA

    PowerWAVE 1000 10kVA

    £2,738.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    10 kVA
    10 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
Top

Pin It on Pinterest

Share This