PowerWAVE 1000 10kVA

£2,738.00 ex.VAT

Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high reliability with low set-up costs for mission critical environments that demand future flexibility and excellent return on investment. Available in a compact tower or 19″ rack-mountable unit with modular batteries for increased power output.

Lead time: 1 – 2 weeks, but many items are in stock and once ordered we will contact you to arrange delivery.

Optional external battery cabinets are available to increase the UPS autonomy time. The battery cabinet design complements the UPS cabinet and the two cabinets can be mechanically connected together to form a single unit when installed as a tower system. Up to three external battery cabinets can be connected in tandem as part of the UPS System. See the “Pricing” tab below for autonomy information.

External, rack mounted Maintenance Bypass switch to provide continuous power without shutting down the connected loads during maintenance or battery replacement.

19” support rails for the PowerWAVE 1000 1 – 10kVA rack mountable model.

The Relay Card provides a set of relay contacts for managing UPS alarm notifications and operating states.

The SNMP Card allows the UPS to be directly connected over LAN 10/100 Mb connections to be managed using the main network communications protocols. It was developed to provide a high level of reliability in communication between the UPS and associated management systems.

Description

Robust uninterruptible power supply with hot swappable batteries and advanced battery discharge management.

Hot-swappable batteries

UPS replacement batteries for fast upgrades with no downtime and no interruption to the critical load. Provides 24/7 power protection for demanding IT environments.

Advanced battery discharge

The PowerWAVE 1000 uninterruptible power supply automatically manages the end-discharge voltage of the internal batteries, preventing deep discharge during power failures. Maintenance bypass switch allows for UPS system to be isolated manually.

High reliability

Automatic (6–10 kVA) redundant parallel operation providing remarkable reliability with option to increase load and protection levels by connecting up to four additional units.

Low cost of ownership

The PowerWAVE 1000 delivers high efficiency of up to 94% (98% in eco-mode).
High operating efficiency provides 1.0 input power as well as <7% input current THDi to reduce running costs.

 

To request more details about the PowerWAVE 1000 make an enquiry using the form below or call us on 0800 731 3269.

Additional information

Weight106 kg
Actual kVA

10 kVA

Type

Single phase

Max. power per frame with N+1 redundancy

Up to 10kVA

Parallelable up to

4 x UPS units

Rated output voltage range

220/230/240V single phase

Working mode

Online double conversion

Efficiency

Up to 98% (Eco Mode)

Maintenance bypass

Standard

Network/web interface

Option

Volt free contacts

Optional

Input current distortion THDi @100% load

< 6%

Input power factor @100% load

0.99

Scalable (N+1)

Yes (horizontal)

Hot-swappable modules

No

ECA scheme approved

No

Transformerless

Yes

Standalone / Modular

Standalone, Rackmounted

Installation

1, 2 and 3kVA units have a standard 13-amp UK plug fitted
6kVA and above units require a hardwired electrical connection – please ensure this is installed with accordance to BS 7671.

Documentation

Pricing

See below current pricing for the PowerWAVE 1000 UPS and accessories. 

Model NoOutput PowerAutonomy (min)Dimensions in mm (HxWxD)WeightUnit Price (GBP)
PW1000/11 kVA689 x 445 x 405 (2U)17390
PW1000/22 kVA689 x 445 x 680 (2U)30744
PW1000/33 kVA689 x 445 x 680 (2U)33848
PW1000/66 kVA13222 x 445 x 680 (5U)100 *1)1715
PW1000/10 1/110 kVA6267 x 445 x 680 (6U)106 *2)2738

Additional Battery Cabinets

Model NoAdditional backupDinensions in mm (HxWxD)WeightUnit Price (GBP)
PWBAT-9-61 kVA only, additional 24 minutes backup89 x 430 x 640 (2U)19277
PWBAT-9-122 kVA only, additional 23 minutes backup89 x 445 x 680 (2U)44420
PWBAT-9-123 kVA only, additional 18 minutes backup89 x 445 x 680 (2U)44420
PWBAT-9-206 kVA only, additional 17 minutes backup133 x 445 x 680 (3U)82747
PWBAT-9-2010 kVA only, additional 9 minutes backup133 x 445 x 680 (3U)82747

Options

Model NoDescriptionUnit Price (GBP)
PW1000/RMKRack mounting kit42
PW1000/RCRelay card with 6 dry contacts (to be installed in SNMP slot)50
CS121scSNMP Adapter card190
PW1000-MBP 3kVABypass module, 1 - 3kVA161
PW1000-MBP 10kVABypass module, 6 - 10kVA393

*1) = composed of 1 x UPS (2U, 22kilos) and 1 x battery cabinet (3U, 82 kg)
*2) = composed of 1 x UPS (3U, 22kilos) and 1 x battery cabinet (3U, 82 kg)

Related products

  • MINIPower PLUS (1.25 -10kVA)

    MINIPowerPLUS

    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    1-10 kVA
    1-10 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Flexible tower or rack-mounted UPS system with a unique scalable design featuring easy to replace mo
    Read MoreCompare
  • PowerWAVE-1000-1kVA

    PowerWAVE 1000 1kVA

    £390.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    1 kVA
    1 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
  • PowerWAVE-1000-2kVA

    PowerWAVE 1000 2kVA

    £744.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    2 kVA
    2 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
  • PowerWAVE-1000-3kVA

    PowerWAVE 1000 3kVA

    £848.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    3 kVA
    3 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
  • PowerWAVE-1000-6kVA

    PowerWAVE 1000 6kVA

    £1,715.00 ex.VAT
    Single phase
    Single phase
    A single-phase installation consists of a single sine wave input and is typically a single phase of a larger three phase supply. A typical example of this would be a local three pin UK socket which uses 230/240 VAC to supply power. Most small power hardware including rack-mounted servers, telecoms, network switches, computer systems or any device running from a standard three pin UK plug, operate from a single phase supply.
    6 kVA
    6 kVA
    Understanding the total kVA requirement of a critical load is a key part of establishing a UPS’ true sizing requirement. For more information see kVA calculator and guide to choosing a UPS.
    Standalone
    Standalone
    Standalone UPS systems allow several units to be operated in tandem (known as horizontal scaling) to provide for a greater load.
    Rackmounted
    Rackmounted
    Designed to fit industry-standard-sized computer racks and cabinets (19" wide).
    Single phase UPS system for server, network, VoIP and telecommunication applications. Combines high
    Read MoreCompare
Top

Pin It on Pinterest

Share This